Phosphorus content in electroless nickel
Direct measurement of the phosphorus content in electroless nickel coatings by X-ray fluorescence; phosphorus strongly influences the mechanical and magnetic properties.
Coating thickness, plating-bath analysis, paints and lacquers: from thin metal layers to multilayer coatings.
No results. Try another word.
Direct measurement of the phosphorus content in electroless nickel coatings by X-ray fluorescence; phosphorus strongly influences the mechanical and magnetic properties.
Measuring the thickness of cured powder coatings to control quality and cut powder consumption, for custom coaters and incoming inspection.
Dry film thickness (DFT) inspection according to SSPC-PA2 on structures such as bridges, ships, pipelines and water tanks.
Accurate measurement on curved surfaces with a dedicated probe that removes the need to calibrate for each radius of curvature.
Accurate measurement on curved surfaces with a dedicated probe that removes the need to calibrate for each radius of curvature.
Measuring anti-corrosion coatings in hard-to-reach cavities of car bodies with a slim, curved magnetic-inductive probe.
Determining the thickness of multi-layer metal coatings on plastic bathroom fittings such as shower heads.
Determining the thickness of multi-layer metal coatings on plastic bathroom fittings such as shower heads.
The MMS PC2 with USB, LAN and serial interfaces and optional digital I/O for process monitoring directly in production.
Measuring sprayed acoustic coatings in vehicle interiors with the compact, elbow-shaped FA14 probe for tight spaces.
Inline measurement lets layers be applied as thin as the tolerance allows, saving material on gold; example of a 2–4 µm gold coating.
Inline measurement lets layers be applied as thin as the tolerance allows, saving material on gold; example of a 2–4 µm gold coating.
Measuring paint thickness by clearly defined procedures and collecting data for process optimisation with the DataCenter software.
Measuring paint thickness by clearly defined procedures and collecting data for process optimisation with the DataCenter software.
X-ray fluorescence analysis of plating-bath solutions in a sealed cell with a thin foil window, to keep the bath composition under control.
X-ray fluorescence analysis of plating-bath solutions in a sealed cell with a thin foil window, to keep the bath composition under control.
Measuring 60–70 µm NiP coatings (at least 10 % phosphorus) on solenoid-valve plungers in automatic transmissions by X-ray fluorescence.
Measuring 60–70 µm NiP coatings (at least 10 % phosphorus) on solenoid-valve plungers in automatic transmissions by X-ray fluorescence.
Non-destructive thickness measurement of PVD coatings on saws, drills and forming tools using X-ray fluorescence (XDLM).
Non-destructive thickness measurement of PVD coatings on saws, drills and forming tools using X-ray fluorescence (XDLM).
Quality control of electroplated parts with custom measurement plans in the DataCenter software, with documented results.
Quality control of electroplated parts with custom measurement plans in the DataCenter software, with documented results.
Measuring 25–50 µm hard Nikasil coatings on the running surfaces of aluminium engine cylinders.
Measuring 25–50 µm hard Nikasil coatings on the running surfaces of aluminium engine cylinders.
Measuring paint over galvanised steel and aluminium (EDP) without recalibration, with conductivity compensation for different aluminium alloys.
Measuring paint over galvanised steel and aluminium (EDP) without recalibration, with conductivity compensation for different aluminium alloys.
Reliable paint thickness measurement on grey cast iron or sand-blasted steel, where substrate roughness causes large fluctuations in readings.
Reliable paint thickness measurement on grey cast iron or sand-blasted steel, where substrate roughness causes large fluctuations in readings.
Measuring the thin lubricant film on sheet metal (rolling, pressing, drawing) with the modular MMS PC2.
Measuring the thin lubricant film on sheet metal (rolling, pressing, drawing) with the modular MMS PC2.
Measuring the inner polymer protective layer of pharmaceutical, cosmetic and food packaging with the FTA2.4-SC eddy-current probe.
Measuring the inner polymer protective layer of pharmaceutical, cosmetic and food packaging with the FTA2.4-SC eddy-current probe.
Measuring the protective lacquer applied by hand to watch dials to prevent oxidation and tarnish.
Measuring the protective lacquer applied by hand to watch dials to prevent oxidation and tarnish.
Normalising and calibrating a coating thickness gauge, even when no uncoated part is available, and choosing the right method for the best accuracy.
Normalising and calibrating a coating thickness gauge, even when no uncoated part is available, and choosing the right method for the best accuracy.
Non-destructive measurement of several paint layers on metal and plastic with terahertz technology (THz-TDS): accuracy, repeatability and advantages over induction and ultrasound.
Overview of portable instruments for measuring the thickness of electroplated coatings, paints and anodic layers, and the sealing quality of anodised aluminium (PDF in Slovenian).
Study of aluminium pickling in an anodising plant: material removal against time, the effect of Al and NaOH concentrations, and weight gain after anodising (Slovenian).
Workshop notes on the Betascope (beta backscatter), Couloscope (coulometric deplating), MMS PC2, Sigmascope Gold B and Poroscope.
Slides (55 pages): NiP analysis with multiple excitation, galvanic bath analysis, Cr(III), light elements with helium flush, and powder samples.